 COMPACT CONNECTOR TERMINAL FOR REDUCED WIRING FEATURES
* One-touch wiring with the various controller types greatly reduces the time required for wiring operations. * Compact space-saving design Design and dimensions match those for the RT-2 relay terminal. * Wide variation of pole: 20, 30, 34 and 40 poles * Available in pressure connector connect type and wire-direct connect type The direct connect type is a compact 62 x 52 mm 2.441x 2.047 inch (20P type). * Exclusive cables can be provided * Integrated AXM connector (complying to MIL Standard, Long lever type)
CT-2 CONNECTOR TERMINAL
TYPICAL APPLICATIONS
I/O interface for PLCs, personal computers and various types of controllers.
Pressure connector connect type
Wire-direct connect type
ORDERING INFORMATION
Ex. CT2 Installation type M C Termination type 20 No. of poles 20: 20 poles 30: 30 poles 34: 34 poles 40: 40 poles
Blank: DIN rail mounting Blank: Pressure connector type connect type M: Direct mounting C: Wire-direct type connect type
TYPES
1. DIN rail mounting type
Connection method Pressure connector connect type No. of poles Part No. 20 30 34 40 20 30 34 40 CT2-20 CT2-30 CT2-34 CT2-40 CT2-C-20 CT2-C-30 CT2-C-34 CT2-C-40 Packing quantity Inner carton Outer carton
2. Direct mounting type
Connection method Pressure connector connect type 1 pc. 20 pcs. Wire-direct connect type No. of poles Part No. 20 30 34 40 20 30 34 40 CT2-M-20 CT2-M-30 CT2-M-34 CT2-M-40 CT2-MC-20 CT2-MC-30 CT2-MC-34 CT2-MC-40 Packing quantity Inner carton Outer carton
1 pc.
20 pcs.
Wire-direct connect type
SPECIFICATIONS
Rated voltage Rated current Breakdown voltage Insulation resistance Fasten torque Ambient temperature 125 V AC 1A 250 Vrms for in min. 100 M (at 500 V DC megger) Pressure connector connect type: 0.3 to 0.5 N*m {3 to 5 kgf*cm} Wire-direct connect type 0.2 to 0.4 N*m {2 to 4 kgf*cm} 0C to +55C +32F to +131F
CONNECTOR
* Applicable connector (socket)
Product name No. of poles 20 30 34 40 Part No. AXM120415 AXM130415 AXM134415 AXM140415
MIL type AXM Flat Cable Connector
* Applicable flat cable Standard wire: standard pitch (1.27 mm 0.050 inch)/ conductor #28 (7 wire/0.127 dia.)
All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd.
CT-2
TERMINAL BLOCK
1. Pressure connector connect type * Applicable electrical wire 0.25 to 1.65 mm2 .01 to .065 inch * Applicable wire-pressed terminals 2. Wire-direct connect type When wiring screw-clamped terminal blocks, strip the lead wires and connect them properly.
mm inch
3 dia. min. .118 dia. min. 5.6 max. .220 max. 3 min. .118 min.
Stripping length 8 to 10 mm .315 to .394 inch
Recommended wire * 0.128 to 1.318 mm .005 to 0.52 inch * 0.4 to 1.3 mm dia. .016 to .051 inch dia.
5.6 max. .220 max.
4 4.5 min. .157 .177 min.
4 4.5 min. .157 .117 min.
DIMENSIONS
1. DIN rail mounting type Pressure connector connect type (20 poles)
981 3.858.039 420.6 1.654.024
mm inch
Wire-direct connect type 20 poles
621 2.441.039 420.6 1.654.024
B1 A1
B10 A10
B1 A1
B10 A10
B1 A1
B2 A2
B3 A3
B4 A4
B5 A5
B6 A6
B7 A7
B8 A8
B9 A9
B10 A10
52 2.047.039
1
521 2.047.039
7.620.3 .300.012
20-M3 .118 terminal screw 6.20.3 .244.012
5.080.3 .200.012
Pressure connector connect type (30 poles)
1341 5.276.039
Wire-direct connect type (30 poles)
981 3.858.039
B1 A1
B15 A15
B1 A1
B15 A15
B1 A1
B2 A2
B3 A3
B4 A4
B5 A5
B6 A6
B7 A7
B8 A8
B9 A9
B10 A10
B11 A11
B12 A12
B13 A13
B14 A14
B15 A15
7.620.3 .300.012
30-M3 .118 terminal screw 6.20.3 .244.012
5.080.3 .200.012
Pressure connector connect type (34 poles)
1701 6.693.039
Wire-direct connect type 34 poles
981 3.858.039
B1 A1
B17 A17
B1 A1
B17 A17
B1 A1
B2 A2
B3 A3
B4 A4
B5 A5
B6 A6
B7 A7
B8 A8
B9 A9
B10 B11 B12 B13 B14 B15 B16 B17 A10 A11 A12 A13 A14 A15 A16 A17
7.620.3 .300.012
34-M3 .118 terminal screw 6.2 .244.012
0.3
5.080.3 .200.012
Pressure connector connect type (40 poles)
1701 6.693.039
Wire-direct connect type (40 poles)
1341 5.276.039
B1 A1
B20 A20
B1 A1
B20 A20
B1 A1
B2 A2
B3 A3
B4 A4
B5 A5
B6 A6
B7 A7
B8 A8
B9
B12 B13 B14 B16 B17 B18 B19 B20 B11 B15 B10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A9 A10
7.620.3 300.012
40-M3 .118 terminal screw 6.20.3 .244.012
5.080.3 .200.012
All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd.
CT-2
2. Direct mounting type Pressure connector connect type (20 poles)
1151 4.528.039 1060.5 4.173.020 (M4 .157 screw mounting pitch) 981 3.858.039 2-M4 .157 screw mounting position 420.6 1.654.024
mm inch
Wire-direct connect type 20 poles
791 3.110.039 700.5 2.756.020 (M4 .157 screw mounting pitch) 621 2.441.039 2-M4 .157 screw mounting position 420.6 1.654.024
B1 A1
B10 A10
B1 A1
B10 A10
B1 A1
B2 A2
B3 A3
B4 A4
B5 A5
B6 A6
B7 A7
B8 A8
B9 A9
B10 A10
521 2.047.039
521 2.047.039
7.620.3 .300.012
6.20.3 .244.012
20-M3 .118 terminal screw
5.080.3 .200.012
Pressure connector connect type (30 poles)
1511 5.945.039 0.5 142 5.591.020 (M4 .157 screw mounting pitch) 1341 5.276.039
Wire-direct connect type (30 poles)
1151 4.528.039 1060.5 4.173.020 (M4 .157 screw mounting pitch) 981 3.858.039
B1 A1
B15 A15
B1 A1
B15 A15
B1 A1
B2 A2
B3 A3
B4 A4
B5 A5
B6 A6
B7 A7
B8 A8
B9
B10 B11 B12 B13 B14 B15 A9 A10 A11 A12 A13 A14 A15
7.620.3 .300.012
30-M3 .118 terminal screw 6.20.3 .244.012
5.080.3 .200.012
Pressure connector connect type (34 poles)
1871 7.362.039 0.5 178 7.008.020 (M4 .157 screw mounting pitch) 1701 6.693.039
Wire-direct connect type 34 poles
1151 4.528.039 0.5 106 4.173.020 (M4 .157 screw mounting pitch) 981 3.858.039
B1 A1
B17 A17
B1 A1
B17 A17
B1 A1
B2 A2
B3 A3
B4 A4
B5 A5
B6 A6
B7 A7
B8 A8
B9 A9
B10 B11 B12 B13 B14 B15 B16 B17 A10 A11 A12 A13 A14 A15 A16 A17
7.620.3 .300.012
34-M3 .118 terminal screw 6.2 .244.012
0.3
5.080.3 .200.012
Pressure connector connect type (40 poles)
1871 7.362.039 0.5 178 7.008.020 (M4 .157 screw mounting pitch) 1701 6.693.039
Wire-direct connect type (40 poles)
1511 5.945.039 0.5 142 5.591.020 (M4 .157 screw mounting pitch) 1341 5.276.039
B1 A1
B20 A20
B1 A1
B20 A20
B1 A1
B2 A2
B3 A3
B4 A4
B5 A5
B6 A6
B7 A7
B8 A8
B9
B19 B20 B11 B12 B13 B14 B15 B16 B17 B18 B10 A11 A19 A20 A12 A13 A14 A15 A16 A17 A18 A9 A10
7.620.3 .300.012
6.2 .244.012
0.3
40-M3 .118 terminal screw
5.080.3 .200.012
All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd.
CT-2
SCHEMATIC (Top View)
20 poles
A Connector No. 1 2 3 4 5 6 7 8 9 10 Connector No.
34 poles
A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Terminal No. (from left on the lower stage)
1 2 3 4 5 6 7 8 9 10 A B 1 2 3 4 5 6 7 8 9 10
Terminal No. (from left on the lower stage)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Connector No.
Connector No.
Terminal No. (from left on the upper stage)
1 2 3 4 5 6 7 8 9 10 B
Terminal No. (from left on the upper stage)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 B
30 poles
Connector No. A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
40 poles
Connector No. A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Terminal No. (from left on the lower stage)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Terminal No. (from left on the lower stage)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 A B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Connector No.
Connector No.
Terminal No. (from left on the upper stage)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 B
Terminal No. (from left on the upper stage)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 B
CAUTIONS FOR USE
1. Installation 1) Perform mounting hole cutout according to the panel cutout drawings. 2) When installing the unit on a DIN rail, use the DIN rail locking lever on the side of the unit. Installation is accomplished by simply fitting the unit onto the rail and pressing gently. 2. Removal of cover 1) Insertions and withdraws of connector can be done by lifting the cover like 1. 2) Wiring to the terminal can be done by lifting the cover like 2. 3) Removal of the cover can be done by lifting it like 3. 4) In case of resetting the cover, please push the cover like 4. 1 2 3) In order to improve noise resistance, class 3 grounding of the control panel is recommended. 4) Turn off the power before connecting/ disconnecting connector cables. 4. Operating environment 1) Use the product at ambient operating temperature between 0C and 55C 32F and 131F. 2) The main unit is made of resin; therefore, do not use it in areas where it may come in contact with (or be exposed to) organic solvents such as benzine, thinner, and alcohol or strong alkaline substances such as ammonia and caustic soda. 3) Do not use the product in areas where it may be exposed to flammable gases, corrosive gases, excessive dust, or moisture, or areas where it may be subjected to strong vibration or shock. 5. Transporting and storage 1) If the product is subjected to extreme vibration while being transported, the relays may become detached, the lead may become bent, and the unit may become damaged. Handle the inner and outer boxes with care. 2) If the product is stored in an extremely adverse environment, visible defects and deterioration of performance characteristics may result. We recommend the following storage conditions. * Temperature: 5 to 30C 41 to 86 F * Humidity: Max. 60% R.H. * Environment: No hazardous substances such as sulfurous acid gases and little dust.
1 First push in the DIN rail locking lever. DIN rail locking lever DIN rail 3 Press the unit onto the DIN rail.
2 Hook the holders on the unit over the DIN rail.
3) To remove the unit from the DIN rail, use a flat head screwdriver to pull out the DIN rail locking lever.
3 Remove the unit from the DIN rail.
3
4
2 Move the screwdriver in the direction of the arrows, and pull out the lever.
1 Insert the tip of the flat head screwdriver into the slot in the DIN rail locking lever.
4) Be careful not to drop or shock the unit. Excessive shock such as dropping may cause damage or malfunction.
3. Wiring and circuit configuration 1) Make all connections according to the schematic. 2) When wiring power lines or power cables, twisted pair treatment (standed wire treatment) should be done in order to improve noise resistance.
All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd.


▲Up To Search▲   

 
Price & Availability of CT2-MC40

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X